Fanuc ot control software. Your servo's are not ready.
- Fanuc ot control software hit input Jul 6, 2007 · We recently bought a Mori lathe with this control from 1990. This is why machines differ so from make to make. Great. 7. software packages are contained on one 3. I took a peek at the sockets on the memory board (A16B-1212-0210) and following locations are empty: 2L, 3L, 2H, 3H. 5 inch floppy disk each. When the machine is running for about 2 hours, the turret is mis-indexing like its running off the top of the snail cam. Feb 6, 2015 · we have an ikegai tu-25 cnc turning with fanuc ot contrioller. I am a mill programmer and I have not been on a lathe in a long time. Fanuc 18T work offset measure help; Activating touch probe on Fanuc in measure Cycle; Heidenhain hand Control Job Button Teach Pendant HR 330; On an OT control, hitting the reset button; Fanuc OT control Auto Button Oct 8, 2015 · Re: Fanuc O-T control axis can't move backward this is a common problem caused by a stuck or non-functional deceleration switch somewhere. There are no manuals for this lathe, but the owner does have an OT Fanuc Operator's Manual. I can get to these values via "MDI - Offset Screen - Work offsets" to manually enter values, but I'd like to set these via program control. I can change the program number with the Alter key but have not found a way to copy it. Just wondering if anyone knows or if it is possible to change the direction the angles work on a fanuc OT control. Sep 27, 2007 · We have a Denford Cyclone slant bed lathe Fanuc OT Model B Control circa 1988 We need to Know the required settings for communicating with a Fanuc OTB control the cable is a standard Xon /Xoff configured 9 pin at the PC to 25 pin wired 9 pin 25 pin 2 2 3 3 Dec 16, 2011 · I have an early '90s Star CNC lathe with a Fanuc OTT-C control. Regards, Bill Last edited by angelw; 10-19-2011 at 04:50 AM . Nov 2, 2012 · Trying to get code into my fanuc ot on a hardinge conquest 42. It has a fanuc ot controller. Jun 9, 2016 · As it sits now i have 4 tons of Femco Durga 25e with Fanuc O-T control sitting on my garage floor. If you have a parameter manual for the Oi control, look under the Marco programing section, it should e listed there. I have read the strings above and it seems pretty self explanatory, but thought I better double check. " go to SETING 2 screen (in MDI mode) and set PWE to 1 Prameter no. As with everything in a Fanuc control, it is an option. I am not allow to tell you the option bit number but if you post what your 900 to 940 parameters are I can confirm it. FANUC has a variety of software to help programming, both on and off the shop floor! Explore our robust range of CNC programming and simulation software, below. If you have the option turned on then use these parameters. Oct 8, 2016 · Hi, I just wrote a macro Program on Fanuc Oi mate - TD control. If it does not allow you to make an entry, you will have to call Fanuc and pay $$$ to have it turned on. Re: FANUC OT-B MDI mode - how to? Post by pfp » Thu 29 Mar , 2018 21:39 pm Hi procedure for tool change in manual mode. To install from a "DOS" prompt : 1)Insert the disk into the floppy drive, this is usually labelled as A: CNC Programming and Simulation Software. I didn't look tonight, but I'm fairly certain I saw the A-word used in the example it gave. Contact CNC Software Sales. Can you help us clear them? Similar Threads: Fadal w/ Fanuc control alarm 1105; Need Help!-Fanuc Powermate D Alarm 414 (LV5V Control Power Low Alarm) Mar 18, 2023 · Hello again, i had a parameter loss on my machine. Hi everyone , We have recently purchased a second hand Colchester CNC 350 turning center. FANUC OT control need dnc help. (Same cable works on my Fanuc 3M-C) I am using NC LInk for communication. Has anyone encountered such a problem and if so, what would you Dec 3, 2024 · Download Communication Software for FANUC CNC 94. Nov 25, 2020 · On control ladder editing was not possible on the 0C without optional hardware and firmware. The Cutting Edge. I am not able to type the following things on old control - 1. I can get only up to about 10 lines of comments and code into the control. The machine have a 15 Deg index system . Fanuc OT Post Processor Hey all, was wondering if anyone ever found a good working post processor for a Fanuc OT control. Its Parameter Bit 391. But more important is to download all the parameters, including the 900's and any 9000 macro's otherwise you WILL end up with 4 tons of useless iron if you don't have them and the machine Control Parameter Settings: #0002 Bit 0 = 1 Bit 2 = 0 Bit 7 = 1 #552 = 10 (4800 Baud - Starting Point) Control Set Page Settings: I/O = 0 Format = ISO PC Communication Software RS232 Protocol Settings: Handshake Method = Xon Xoff (Software Handshaking) Data Bits = 7 Stop Bits = 2 Parity Bit = Even Baud Rate = 4800 (or whatever the control is The software EMCO WinNC FANUC SERIES 0-TC Turning is a part of the EMCO education concept on PC basis. Control indicates OT C series and the CRT indicates MFT-4. Using Cadem dnc software on a pc with a USB-25 pin serial converter cable to a null modem adapter inline. Jun 3, 2005 · We have a problem with a CNC machine and the ladder logic would help to track down the fault. The depth in Z is only . Loading programs into the control is not working. Unfortuately, I do not know the exact keystrokes that will bring up the ladder logic on the CRT of the Fanuc OT. All our lathes have Macro B option. I beleive the machine is 1990 but I'm not positive. 6, but by default it will be set to use DC Codes (Software). If the software doesn't have this capability, press the "Input" button and then start the Send process from the PC. 1998 Kitamura Mycenter1 with Fanuc O-M control I recently got this machine into commission after it sat for a year (stuck ATC and RS-232 communication issues) after moving it into my shop. I have fanuc ot control miyano jnc45t machine and it has external as well as internal parts counter on control. I check the chuck, clamp unclamp works fine. I have the GE Fanuc Operators manual and the GE Fanuc Maintenance manual. Regards, Fanuc Ot Control Operator Manual: Fanuc CNC Custom Macros Peter Smid,2004-01-11 CNC programmers and service technicians will find this book a very useful training and reference tool to use in a production environment Also it will provide the basis for exploring in great Feb 24, 2013 · The machine is a Femco Durga Lathe with Fanuc OT Control. LaserCut; Laser Hardware. Press [EDIT] to select EDIT mode. 3. The second one is a Fanuc "Paid" option. Think we also have a 6- (T ?) control, but I don't program that one as a general rule. Breakdown & Repair SOFTWARE OPERATOR’S PANEL Jun 17, 2022 · There were some test points on the speed control board (+15/0/+5/+15/+20) that all checked ok. This tells the Fanuc that it's reached the end of the program when it's reading data. Does anybody have this information that I could use and check against what I have set is correct? I have the cable from the machine connected to the COM 1 port. then loaded my "900" parameters and shut control off. points(x,y,z), tool turret works but only spindle dont start. You can change the Flow Control (Hardware - Software) at the control, but you won't find the parameter in most Fanuc Manuals for Flow Control. As soon as the control comes up, I get a “424 Servo Alarm - Z axis Detect error” and a 401 “Servo Alarm (Vrdy Off)”. 0015 DOC. When using Type1 cycle, it won't be a case of the control glitching once in a while, but every time the profile description between the P and Q referenced blocks contained a concave feature (non-monotonous X direction move in the case of a G71 cycle). I can't use brackets inside a canned cycle on the OT control. This one has Mate in the title. GE FANUC SYSTEM OT-Model B The GE Fanuc Series O-T MODEL B (referred to as OT-B) is a CNC for high speed, high accuracy and high efficiency machining especially designed as numerical control for small, all-purpose lathes, automatic lathes, and lathes controlled by programmable controllers. I turned off PWE and restarted control and still end up with alarms 401, 410 and 420. Photo & Graphics tools downloads - CNC-SIMULATOR by CNC SIMULATOR and many more programs are available Sep 30, 2011 · There are no manuals for this lathe, but the owner does have an OT Fanuc Operator's Manual. You have a Wasino Gangturn, so no turret and no toolchange, but usually real fast cycle times. It currently is configured with the minimum amount of ram as per the 901 parameter (11010000). it had a custom pallet change/loading mechanism and control wired into the main-board. Laser CO2 Tubes, Diodes, RF and Power I just picked up a 1990 Leadwell LTC-20P with a Fanuc OT control. Hi Guys, I have a problem with the codes G83 and G84 on my fanuc OT control the machine is a Nakamura lathe and I tried different thinks typing the lin G83 and G84 on Fanuc OT 595,779 members Nov 17, 2013 · The Fanuc 0T has been on the market for a very long time. ) this should move towards the spindle and up, but currently it moves away I loaded the first 20 parameters then shut control off. OR OT. 417 servo alarm: x axis dgtl param 427 servo alarm: z axis dgtl param I've checked the parameters for this alarm and this is what I've got in there. copy etc caracters in a program. On most machines, the hard limit switches are tied in series with the E- Stop circuit. Explore FANUC's CNC software solutions to help improve CNC machine efficiency, simplify part creation, monitor you machine tools, boost machining and programming efficiency, and more. Thanks Delw Similar Threads: Re enter parameters for FANUC 15 M control; Need Help!-Is this normal parameters from a 10-T Fanuc control I have a Hardinge lathe with a 0T-B control. Your servo's are not ready. The canned cycles are wrong, possible because of the PP that we used could be for a mill. It generate a post with a lot of extra G code that I don't think is needed for Fanuc OT. 453" hole. I have had the machine for over 15 years, so I am familiar with it, but this has me stumped. 01 cut. Hi . Similar Threads: Need Help!- I am repairing Kirloskar internal grinding machine with Fanuc OT control. Jan 8, 2007 · It doesn't stink, it just the way it has to be. thanks for any help. typically I think I get that when I am putting in a duplicate program. B-61397E_02 FANUC Series 0_00_0-Mate Operation and maintenance handbook . . I had it on a other fanuc mt. c. Aug 1, 2015 · OK, thank you everybody. For example . dcoupar. A02B-0098-C199 In addition you would need the Fanuc EPROM Writer to burn the modified ladder to EPROM for production use. 375. 10-21-2022, 08:36 AM #19 Jun 2, 2009 · Good Morning! Okuma & Howa Act2SP-2 with a Fanuc OT Control. Its a option to copy. #501 = #2801 (To copy geometry offset in common If all the above fails, contact Fanuc with all the control details such as model and serial number, ect Sorry I can't be more help other than offer suggestions. was entered. Nov 5, 2023 · Here is a list of those pesky option parameters for a Fanuc 0 Series Control. Then loaded the rest via rs-232, and changed diag. It runs off an RPC so when its off, theres no power to it at all. Home; Services. Thanks. 706jim Titanium. I just got it powered up and I'm getting a 1003 ESP. #0002 Bit 0 = 1 Bit 2 = 0 Bit 7 = 1 #552 = 10 (4800 Baud) Starting point Control Set Page Settings I/O = 0 ISO Format Cable pin out for Xon Xoff (software handshaking) Machine End-----PC End DB25 Male Connector-----DB9 Female-----DB25 Female 2-----2-----3 3-----3-----2 4 Jun 4, 2014 · We have an old Fanuc OT model B type, A02B-0091-8501 No. Dec 15, 2015 · The code is correct, the X moves should show as a positive until the machine goes past the X0 point which is the centre line of the spindle then the numbers chould start to show negative, looks like a simple 2 pass face cut, first cut taking 0. you need to check all Z axis switches at BOTH ends of the stroke limits. ). below I am putting in that block of code. Any help would be appreciated. Wondering what software out there guys have been using that free and works. Apr 15, 2008 · The last time I used a canned drilling program on a Fanuc OT control it was tied to a macro program (G65) from which variables such as depth, feed, dwell, etc. I loaded the first 20 parameters then shut control off. Notice that you can hit the hardware OT switch if the zero-return (cam) switch sticks in the "on" position. We can see already that there are a couple relays missing and need info to replace them. 1 This makes the tool move away from the spindle, whereas I would like it to travel towards the spindle. The software should also be set to handshake using "Xon/Xoff" protocol, sometimes called "DC codes" Jan 1, 2012 · Hello I can't get the program from the PC to the CNC (fanuc OT model B). Both books show parameters however they are the system parameters. I cannot find the setting for the flow control. The generic Fanuc turning post from Autodesk is horrible and only causes errors even doing the simplest of operations. 02 DOC. if you are desperate to run the machine without production loss for the next couple of weeks: 1. All I got with my machine was the Fanuc OT operators manual. 6 "SA" is the servo ready bit from the control to the PMC. Sep 2, 2011 #3 The older OT required you Oct 28, 2011 · We lost all the parameters for our Fanuc OT. He wants to know if it can be programmed from windows98. Good Luck Kent May 23, 2015 · I am trying to hook a pc to a Fanuc OT-B Programmer is tired of programming at the control. Oh, and does anyone have a copy of the Fanuc OT parameters handbook - I would like to find out what each of the parameters are that don't match the original list. If you send a PM with an email add I can send some manuals. At the alarm message it says (Not Ready), but no alarm message, how do I get out of this Not Ready Mode. Fanuc just provides a tool (PMC) for the machine builder to write software (ladder program) to control whatever equipment the machine We lost all the parameters for our Fanuc OT. main board A20B-2000-0170/02A MEMORY BOARD A16B-1212-021 with a small square & then a rectangle ?? could be a A16B-1212-0210 ??? series OTF software version 0665-13 I found a couple pics on the net of the boards I think, can't get to machine right now cause it's about 100km away & snow storm coming through. edit mode 2. I have a Colchester 2000L Lathe machine, it has Fanuc OT Control, when i turn the power on, screen show 0602-06, PMC :2-14 and says Not Ready. Oct 3, 2011 · Q100 is telling the control the minimum depth of cut is . When my cam program write a mil cycle it sets a feed in every g1 code. PC-Based Sofware CNC-Based Sofware Jul 18, 2021 · This video explains basics of CNC Lathe Programming for Fanuc OT Control with an example of simple job. I'm sure a google search of your fanuc control and you'll be able to find something for mastercam. PC-Based Sofware CNC-Based Sofware Any help would be greatly appreciated. Leave the machine's main power ON so the drives are powered up all the time. When downloading parameters I get all 642 lines the same. With a lot of machines, there are general posts based on the control it uses, but many different machines use the same Control but the way the machines run are different so usually there needs to be some edits done to the post processor. Joined Jun 14, 2006 Location Thunder Bay Canada. If you Know How, but its not happening then: Sorry to be so vague but it has been 7 or 8 year since I last ran a Fanuc OT Control. View Profile Laser Control Software. Oct 28, 2011 · IndustryArena Forum > Machine Controllers Software and Solutions > G-Code Programing > Parametric Programing > Alarm 310 & 320 on Fanuc ot control Thread: Alarm 310 & 320 on Fanuc ot control Results 1 to 2 of 2 Aug 24, 2012 · 4. Maybe the manual isn't the right one for this control. Press and hold down [EOB] and press [INPUT]. delete. In diagnostic parameters when i clamp-unclamp 0-1 change. Similar Threads: Need Help!-Data Table info for an ECOCA SJ-20MC Lathe with Fanuc 18T; Selling T1 Control, Spindle Motor, and 380VAC Transformer from EmcoTurn 220P Oct 14, 2014 · All of a sudden on my conquest 42 I cant get the control to delete or load programs. 0010= 10010001 9000 Protect on 0010= 10000001 9000 Protect off. PWE=1 Memory Switch: the machine doesn't have one, allowed me to write normal Aug 13, 2013 · I’m in need of the parameter manual or parameters for a hwacheon hi-eco31a with Fanuc 0-t Korea’s control. Target of this concept is learning to operate and program the original control at the PC. I looked in the manual and found the baud rate, stop bit, and parity settings. HI, I am trying to hook a pc to a Fanuc OT-B Programmer is tired of programming at the control. Aug 3, 2006 · Good morning, what type of machine are we dealing with, we have several Fanuc control in our process, depending on the year and rev. pdf. Thank you. F148. It must turn on, then DROP OFF for the zero return to work. I made a software flow control cable per Fanuc standards and info from several forums. I've dug through the manual, and it doesn't really lay out where the power supplies are, or what they look like. if i ran the program the cursor stop at m24 and it will register the part count. At the control: a. When i restarted the machine today, i get Alarms 417 Digital Servo Param and 427 Digital Servo Param. 10-21-2022, 04:36 AM #19 Quite scary when all I asked it to do was change tools! Any idea why this would happen? Control is Fanuc OT Similar Threads: problem fanuc om tool change; Need Help!-Fanuc O-T tool change problem; Need Help!-Fanuc Oi M TD - Waiting during tool change; Fanuc 15m Tool Change Problems; Need Help!-Please help me, tool change Fanuc OMB Feb 23, 2016 · Just getting into using a OT-B and will need to communicate with it via the rs232. We are getting a 920 Watch Dog Timer alarm. i think i have all the parameters except the Hi all, I am helping out a friend who has a EmcoTurn CNC lathe with a Fanuc OT control. Jun 28, 2012 · Hi All 1. At first I made the mistake of thinking this was the same as E-stop. May 24, 2014 · IndustryArena Forum > Machine Controllers Software and Solutions > Fanuc > what parameters work/run the G01 on a fanuc ot a control Thread: what parameters work/run the G01 on a fanuc ot a control Results 1 to 3 of 3 Aug 27, 2010 · Takisawa TM20 Fanuc OT control We buy this machine,we instaled and now we have a problem,spindle dont start. On the flip side I do have some old Fanuc do not usually supply the control panel, only the crt/keypad, Any button, function switch etc, is supplied and wired in to the PMC as the machine tool builder sees fit. alarm message on start-up. Fanuc OT . ex. Im pretty sure that I can use a "G76" cycle to cut a 1/4 NPT thread. Machine goes to ref. The program works fine on Fanuc Oi Mate control. I’m convinced the 424 is the real alarm, as the 401 clears with reset. If you do, its a later control, the 0TA still used the G50 X-- Z-- to set tool coordinates. Jul 24, 2021 · I am new to Fanuc with my first lathe running Fanuc OT. Can you help us clear them? Similar Threads: Fadal w/ Fanuc control alarm 1105; Need Help!-Fanuc Powermate D Alarm 414 (LV5V Control Power Low Alarm) May 17, 2015 · The control PCB in the drive A06B-6079-H207 has defective component(s). Similar Threads: Bar Pulling On A Femco CNC Lathe W/OT Control 2. a few use different parameters to use the G71 command. Today I had it running for a few hours. Last week I lost my RS232 settings used to send and receive programs to the machine. Similar Threads: RS-232 Setup for Miyano w/Fanuc OT; Newbie-Miyano BNC - 34T + GE FANUC 0T; Need Help!-Miyano BNC-20s with CNC Programming and Simulation Software. if I do G01 A0. They don't deal with what each builder wants to do as far as how the auxiliary devices are built, controlled, sensed, etc. Seems bassackwards to me! What is the diameter of your part? The cycle is pulling out. Any ideas what could be the problem, I think it could be in the Oct 15, 2011 · had to wipe memory due to a 930 cpu interrupt alarm. If it helps any, the code is listed below: What happens is the 1/4" diameter tool ends up about 0. I also want to implement the same on my older machines which have Fanuc O T control. If knows how to get Fanuc OT control manual, need help. Seems like I've tried everything to clear it but I must say I'm not much of a Fanuc person. Yes for Fanuc 21,18 But on Fanuc O-T for enable PWE press "Param/Diag" and with "Page up" or "Page Dw. May 27, 2014 · Hello there I have got an yang turning centre with a fanuc ot control the problem I have is that I am using a 10mm dia boring bar all the tools are set correctly but it wont let me move the boring bar to under 11. it only a 4 flute 1/2 - 28 tap going in a . Select EDIT mode on the mode select switch; Turn OFF the memory protect key switch; Press Jan 14, 2019 · You won't be able to change the number of Data Bits used at the Control, so just set Data Bits as 7 at your device. It stalled suddenly in the middle of a program. with a Fanuc O-T control. Aug 11, 2010 · Can someone tell me how to go about finding out which diagnostic parameter is for certain applications. #s 310-319. prgrm button 3. Shared. We have OT, 18-T, 16-TT, and 21i-T controls. i think the machine is "hearing" something, sometimes when I am trying hardware handshake it changes screens. When I changed it to T0600 or T0606, the control was happy with it. I don't have a schematic in my manual, so I'm not sure what comes between the control transformer and the speed control unit (if anything). The machine may run a few minutes or a few hours. Look at your offsets, do you have the Workshift, Geometry and Wear offsets. Any clues would be great thanks Will Similar Threads: Need Help!-Fanuc Powermate D Alarm 414 (LV5V Control Power Low Alarm) FANUC ALARM 310,320,330 AXIS NEED ZRN ON MF-M4 CONTROL we have an ikegai tu-25 cnc turning with fanuc ot contrioller. Nov 1, 2012 · Colchester Tornado 200 Fanuc OT Control - Turret indexing problem Machine year: 1996. How to start a new CNC program : Fanuc 6M/16/18/21/16i/18i/21i CNC control. 6 - A simple to use application that allows you to quickly transfer data or files between your computer and the FANUC CNC machine you manage Aug 22, 2024 · The Fanuc "Turning" post processor should work for the 0T control, but we do not yet support G72 (canned cycle for Face turning), only supporting G71. Note, although the pc keyboard is used to install both software packages, when the Desktop Tutor offline software is run, the pc keyboard will be disabled. So if you program ( ,A45. Once the alarm occurs, we can power the machine down and bring it back up and the alarm goes away. Parity Alarm is usually caused by low memory backup battery. Jan 25, 2021 · Hello, Does anyone know how to set the work offsets (X & Z) via program on a Fanuc 0T control. Jan 27, 2010 · Fanuc OT program copy; 01-24-2010, 03:19 PM #2. 4 mm dia the x axis over travel alarm comes up. I checked To get a Fanuc 0 to punch you need to have the serial option turned on (check P901. Thanks ok a bit more info on this machine. We bought a second hand GeFong GNP1712-D ( 1995) . in the program i have m24 which is supposed to be my part counter which is listed on parameter 219. Mar 20, 2018 · Hardware/Software: Denford zeroturn Fanuc OT. Does someone have a cycle they can send me ? Fanuc Ot D Control Manual: Fanuc CNC Custom Macros Peter Smid,2004-01-11 CNC programmers and service technicians will find this book a very useful training and reference tool to use in a production environment Also it will provide the basis for exploring in great Feb 3, 2007 · I am repairing Kirloskar internal grinding machine with Fanuc OT control. I'm sure I could get hyperterminal or something like that to work but I'm curious what everyone else is using with more modern operating systems. The way i trying to do it is the following: 1. I've loaded up the parameters but keep getting these errors. key in program number 5. We are also getting alarm 310 & 320. The 424 is solid. Laser Control Software. We have never had a machine with a Fanuc control. Factory in which i am working got this machine about 5 years ago, but noone has worked on it because one axes was not moving. When I purchased the machine it was uploading and downloading programs without any problems, but after I moved it back to my shop it will no longer do that. Thanks, Similar Threads: Need Help!-okuma es l6 copy multiple program from machine to floppy; How to print copy of program ? May 23, 2009 · Will be calling or emailing Fanuc tomorrow, but thought I would ask here anyway. Thanks in advance for any help. When the CNC and PC connect, “INPUT” will flash in the lower right corner of My guess based on the age is A or B. However, I am not getting the desired offset. Everything was fine until I had to index the spindle for milling . Also Plug you punch panel into (M74) on the Memory board in case of 0MC control. 6 = 1 or Parameter 901 bit 6 which is second from the left), the protocol parameters set correctly on the right port (0/1 for Honda Connector M5 or 2/3 for M74 on the MEM-A4 Board), baud usually 4800/9600 (P552/553=10/11), stop bits of 1/2 (see P2. it is an american lathe 3220 with a fanuc o-t control. I am using a Null modem cable and a serial card in the computer. Fordav11: The problem is that with our Fanuc lathe it is easy to hit the X+ limit due to the rather limited X-axis travel and when turning large workpieces with a tailstock it is just best to move the turret as far as possible before indexing (during manual set-up, quick tasks etc. BTW, you can use a decimal with R Q15 is telling the control you want to make the first pass at . There is one option i mis on my ot. Nov 10, 2021 · Did you ever find a post processor that works with the OT control? I have 2 Miyano Lathes which both run Fanuc OT and so far have no found a good working post processor. The machine could be in Emergency Stop, or an axis could be on a hard limit switch, or there could be a "Machine ready" switch of some sort that needs to be pressed for that bit to be triggered by the servos. May 17, 2007 · I am having problems with my leadwell LTC-15. Hello Everyone, I have a Takisawa TC-1 Turning Center with a Fanuc OT controller that I had picked up back in November of last year. However the machine really needs the diagnostic parameters to work. However, the alarm is very intermittent. 600 is to set Number of Required Parts Feb 11, 2010 · I am having trouble tapping with a Fanuc OT C control, I have been getting a PS alarm 011 the book says no feed rate commanded. What are conditions for starting the spindle. I can download programs to the PC just fine and it goes instantly. i. #3000 = 1 (To generate alarm) 2. 04 cut and then a 0. Press [DGNOS/PARAM] two times to display the DIAGNOSIS screen. Takisawa TM20 Fanuc OT control We buy this machine,we instaled and now we have a problem,spindle dont start. I have tried a few of the PP for the Fanuc OT control and none of them are right. F0. I have written a couple of small programs at the control, but the buttons are quite annoying so I am trying to just have Fusion generate the code for me. Jun 22, 2004 · I have a Deawoo Puma 250 Lathe 1998 , Fanuc OT-C control, A06B-6079-H106 Single axis Alpha Servo module. I hit the edit key go to input get the blinking lsk start it, and get the 087 alarm. " Fanuc Series OTB Features. By I am looking for a canned cycle for a fanuc OT control on a femco lathe. Until today I never gave it much HI Have a Hardinge Conquest Lathe with a Fanuc OT Control, Hardinge won't give me the PLC for the machine (Said I have to get a service call) The Spindle runs fine in Setup or Manual Mode, but when I try to run a program, Spindle won't start and consequently, the machine freezes. external counter works fine but internal counter machine never stops when count is up please help. 0 or 12. Seth Madore Customer Advocacy Manager - Manufacturing Jan 7, 2011 · I just picked up a 1990 Leadwell LTC-20P with a Fanuc OT control. The machine is almost ready but it has a problem: Whether I use MDI or MPG method to move in the Z axis, it always moves the half programmed, I mean, the screen shows the desired measure, por when I Check with a Caliper or a simple rule, The Turret just move the Half of that Feb 8, 2013 · I purchased a Star JNC -25, CNC Machine(1988 model) with a Fanuc OT control at an auction and am urgently trying to find some operation manuals, can anyone help with these? It also came without a turret tool holder and I would like to purchase one of these as well. b. all have the same exact results. The following cable pin out and parameter settings will work for you. Now machine returns to zero position, works in JOG and MPG modes, both spindles ir turning. (Mill / Lathe) Control Software (NC) 09-25-2007, 09:08 PM. Part number…. Live day to day on an Okuma. Fanuc just makes the control hardware and software to control axis motion and I/O hardware. Have tried all sorts of settings in the control and the post processor not sure I am getting anywhere. We have entered the ones we downloaded before this happened but don't have 900 thru 914. Get the control PCB repaired or replace it. Browse to your C:\FANUC\Backups\ folder and find the PMCparams file to be sent to the CNC. Thanks, Bill Gillen % O0014 N10 (FANUC OT - ) Fanuc - Discuss Fanuc controllers here! Nakamura-Tome TW-20 with Fanuc OT-C lost parameters. We have no data on it and not even sure what we have. Mar 26, 2007 · 4) Your program should end with a percent sign, or "%". Thanks Similar Threads: Need Help!-RS232 DB-9 Wiring diagram for EZmotion-NC E60 Oct 19, 2013 · I've determined that it is a OT-C control. Mar 30, 2006 · Our DNC software has an "in process gaging" option that works like this: 1) Gaging devices send RS232 data to any serial port on the DNC system 2) Our software uses your criteria for calculating a G10 command 3) When a G10 is created for any gaging device, it's saved as a file 4) The DNC system is set up to "drip-feed" your program to the CNC Aug 18, 2014 · The series 0M control actually has 2 COM ports. 2. The milling machines of the EMCO PC TURN und Concept TURN series can be directly controlled via PC by means of the EMCO WinNC for the EMCO TURN. The fanuc tag would lead me to believe 1987. FANUC-PAGE-6 "On a Fanuc control a Not Ready indication without the presence of an alarm usually means that the E-Stop circuit is open. machine alarm 930 cpu interrupt I replace new batterry machin alarm the same Similar Threads: Fanuc alarm 401 + 414 + servo amplifier alarm 08 Jun 15, 2009 · 6) The zero-return light comes on for that axis, and the control "knows" where it is. Feb 28, 2009 · First use MPG move all three axis to center, turn off control, press and hold down P, Q and CAN key turn on control, wait untill control completely on then you can let go the P, Q, CAN Zero return all axis, it should work Ahn Vuong Jan 13, 2019 · Hi, I´m working in a small factory witch just bought an old CNC lathe, is a leadwell LTC 20. Sean at BC helped with a PP that is closer to what the machine wants, but it's still not right. I can't get it out of the "Not Ready" state. If the PC software is able to be in a "Waite" state, waiting on the control to initiate the program transfer, then the program will start to transfer by pressing the "Input" button. Similar Threads: Fanuc o-t parts counter; chiron with fanuc 21Mb - problem with the part counter and time counter; 0M parts counter I’m in need of the parameter manual or parameters for a hwacheon hi-eco31a with Fanuc 0-t Korea’s control. Re: Fanuc O-T Control 0064#5 When an alarm is issued or an operator message is entered, the screen display switches/does not switch to the alarm screen or message screen Quick Navigation Fanuc Top Aug 6, 2016 · Hello EndlessWaltz, Perhaps you're confusing Type1 and Type 2 Multi-repetitive cycles with FS15 and FS16 Format Multi-repetitive cycles. part counter on the position screen will not register the part being machine. Step 2: Initialized/clear memory by press and holding "RESET" & "DELETE" keys simultaneously while powering ON the control. didn't have all the correct parameters for the machine because the company that retrofitted it is out of business. we have fanuc coming down today or monday not sure if they can fix it because we don't know exactly what options where on it. I repared axes about week ago. Free fanuc programming software download. I am using Fusion 360 for CAM. 1" too high in the X direction. Advertisement. Shifted federates around etc. 2471. Okuma & Howa Act2SP-2 with a Fanuc OT Control. I have 2 lathes with these controls and none of the generic fanuc posts work. key in address O 4. 0)- note that with ISO parity is always even and there Jul 25, 2015 · OK, thank you everybody. I know the OT doesn't allow macro without making some heavy purchase,or maybe this is just a parameter, everything seems to be a parameter in Fanuc , so basically would just like to enable G83, if at all possible. Hope you can help! Oct 17, 2006 · i have a okuma howa act3 with fanuc ot control there is a db25 ports on it (old style printer port) i can get it to comunicate with my pc dnc software im not sure if im using the proper sequance o0001 input than lsk blinks or any other sugestins would be great Similar Threads: Need Help!-Velocity Control Drives and Fanuc 2000C control; Need Help!- My guess based on the age is A or B. Apr 21, 2008 · I have a Fanuc 18T control on a Nakamura-Tome TMC 2011 lathe. I poked around on the control and found parameters and diagnostics, but nothing that says ladder. Jun 24, 2008 · We have a Miyano BNC-34T with a Fanuc OT control. I fix this type of fault on a weekly basis. On the Fanuc OM series control, You need parameter #0010 bit #4 to be a 0 to edit 9000's programs and 1 to protect the programs. Dec 9, 2012 · background: just got an old fanuc tape drill mate. I see you have put a pdf for a Fanuc OM series, are the settings pretty much the same for the OT or do you have a pdf for that? Any help would be much appreciated. May 2, 2013 · Step 1: If control is generating System Errors such as "Alarm 910 Ram Parity" or "Alarm 911 Ram Parity", control memory must be first initialized. Similar Threads: Need Help!-Fanuc drill tap center equipped with Fanuc OM-C i/o card details Just wondering if anyone knows or if it is possible to change the direction the angles work on a fanuc OT control. I was running parts happily yesterday and shut the machine down for the evening. Aug 7, 2011 · Fanuc 0T control procedure? Manual for the control. The display showed 945 serial spindle alarm 1CH. 7) If software OT limits are used, they become effective as soon as you zero-return. N0000 P 00000000 Nov 4, 2012 · Control Parameter Settings #0002 Bit 0 = 1 Bit 2 = 0 Bit 7 = 1 #552 = 10 (4800 Baud Rate - Starting point) Machine Control Set Page Settings I/O = 0 ISO Format PC Software Comms Settings Handshake Method = Xon Xoff (Software Handshaking) Baud Rate = 4800 (or to match the corresponding setting of the control) Data Bits = 7 Stop Bits = 2 Parity May 28, 2007 · heres the pparameter desc of our 12 year old galaxy LAthe with fanuc control 8x45 incompplete integration coefficient (PK3) 46 speed loop gain pk4 47 speed control observer paramaete poa1 48 speed control backlash correcting improvement blcmp 49 seed preset calue of integration at low speed poa3 50 speed observer parameter pok1 May 31, 2013 · My OTB control will not accept this value. I have a GE Fanuc O-T control that uses the B gcode system. e. FANUC Series 0 / 00 / 0-Mate (for Lathe How do you copy a program in a Fanuc OT control? My soft keys do not have the Copy or Move function they show in the manual. Sep 29, 2012 · I have a cnc lathe that has a Fanuc OTc control. 01 R200 is telling the control that you want to make the last pass at . I had a quick look in the power cabinet and back of control but cannot see where you would connect the cable for a RS232 connection. I now have parameter backup and i have succesfully passed the normal parameters via the rs232 port. If someone could point me in the right direction that would be great. the machine in question is a knc-45 miyano with a ot model a control ran numerous sample programs in the book thinking there are different codes for the miyano but to no avail. Instruction Manual and User Guide for Fanuc 0-TC. Aug 23, 2007 · Colchester Tornado 200 Fanuc OT Control - Turret indexing problem Machine year: 1996. program drawing no. Jul 31, 2013 when I turn on the machine about five minutes. The batteries went. Trouble is I don't know how to use it Although I am receiving some tuition on the machine, what I really want is a Fanuc OT-C control simulator so I can practice programming off-line on a PC. 5) Your DNC software should be configured to send ASCII Even parity, or ISO 840 tape code. Feb 25, 2019 · CNC (Mill / Lathe) Control Software (NC) Centroid CNC Control Products; Bosch Rexroth; CamSoft Products; Controller Cards; Controller & Computer Solutions; Dynapath; Dynomotion/Kflop/Kanalog; EdingCNC; CNC-EDITOR; CS-Lab CNC Products; LinuxCNC (formerly EMC2) Deckel / Dialog; FlashCut CNC; Fagor Automation; Mori Seiki Software; Mazak . I only have one Fanuc OT manual at my regular job, and it isn't like this one. It is not. I remember not being able to "single-block" the program because it was tied to a macro program. We have 6 Fanuc 0-TC manuals for free PDF download. uxuxw ggdebcd qqmmnv hsd cmtyj mcv xyaglm qxaqnf kwql beni